Information The seismic performance levels of cable tray systems are presented according to current seismic design codes. A performance-based optimum seismic design procedure for cable tray
Information This event has reminded building owners and possessors in Thailand of the necessity of understanding earthquake-resistant building standards, their legal obligations regarding structural
Information A performance-based optimum seismic design procedure for cable tray systems is given and verified by three studied cases.
Information As with cable restraints, floor- or roof-mounted electrical distribution support systems will normally involve a box frame that supports the system (single or multiple runs) with some kind of a trapeze bar.
Information Seismic risks in the country can be classified as two main categories; medium scale earthquakes from active faults in the northern and western parts of the country and large scale distant earthquake from
Information This study was conducted on the seismic performance of the new DPT 1301/1302 - 61 earthquake design standard in Thailand, the ACI 318-11:2014, and the ASCE 7-16 Standard.
Information This study was conducted on the seismic performance of the new DPT 1301/1302 - 61 earthquake design standard in Thailand, the ACI 318
Information This article discusses the importance of seismic resistance for cable trays, detailing when seismic braces are necessary, the factors that affect seismic resistance, and how to ensure your
Information This event has reminded building owners and possessors in Thailand of the necessity of understanding earthquake-resistant building standards, their
Information The first seismic regulation in Thailand was issued in 1997 and followed by the design standard which has been published since 2009. Recent understandings of
Information A computer program that incorporates the provisions of the draft code for earthquake-resistant design of buildings in Thailand is presented in this chapter. Equivalent lateral forces, story shears, and
Information The first seismic regulation in Thailand was issued in 1997 and followed by the design standard which has been published since 2009. Recent understandings of regional seismic hazard and new findings
Information Visible large cracks, significantly spalled concrete, serious honeycomb, or other gross defects in the concrete to which the cable tray or conduit supports are attached should be evaluated for their
Contact us today for product inquiries, custom assemblies, or technical support